{"title":"FluoView Confocals","description":"\u003cp\u003eUsed and refurbished Olympus FluoView laser scanning confocals, configured to your application and installed by our engineers. Refurbished confocals are guaranteed installable.\u003c\/p\u003e\u003cp\u003eDon't see the FluoView model you need? We source them regularly. \u003ca href=\"\/pages\/contact\"\u003eRequest a quote\u003c\/a\u003e or call (877) 564-2767.\u003c\/p\u003e","products":[{"product_id":"olympus-fluoview-fv3000-laser-scanning-confocal-w-ix83-p2zf-inverted-phase-contrast-fluorescence-motorized-w-optional-zero-drift-confocal-51818","title":"Olympus Fluoview FV3000 Laser Scanning Confocal w\/IX83 P2ZF Inverted Phase Contrast Fluorescence Motorized w\/ optional Zero Drift Confocal","description":"\u003ch2\u003eOlympus FV3000RS Laser Scanning Confocal with IX83 P2ZF Inverted Microscope – Refurbished\u003c\/h2\u003e\n\n\u003cp\u003eThe Olympus FV3000RS Confocal system, combined with the IX83 P2ZF inverted motorized stand, offers high-speed, multi-channel fluorescence imaging with both galvanometer and resonant scanning. Designed for advanced research applications, this system supports optical sectioning, live-cell time-lapse, and high-resolution imaging with integrated modules for laser control, signal detection, and system stability.\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCondition:\u003c\/strong\u003e Refurbished\/Used (This product has been inspected and verified to meet manufacturer specifications)\u003c\/p\u003e\n\n\u003ch3\u003eIncluded Items\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOlympus FV3000 Confocal Scanner Unit\u003c\/li\u003e\n  \u003cli\u003eHigh Speed Resonant Scanner\u003c\/li\u003e\n  \u003cli\u003eOlympus IX83 P2ZF Inverted Microscope, Motorized, Phase Contrast, Fluorescence\u003c\/li\u003e\n  \u003cli\u003eCoherent OBIS Lasers:\n    \u003cul\u003e\n      \u003cli\u003e405 nm (1306092)\u003c\/li\u003e\n      \u003cli\u003e488 nm (OBIS 488-20 LS CW 1306398)\u003c\/li\u003e\n      \u003cli\u003e514 nm (1306091)\u003c\/li\u003e\n      \u003cli\u003e561 nm (OBIS 561-20 LS CW 1306400)\u003c\/li\u003e\n      \u003cli\u003e640 nm (1306090)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eCoherent FV31-MCOMB Laser Combiner\u003c\/li\u003e\n  \u003cli\u003eFV31-DF Spectral Detection Filter Wheel\u003c\/li\u003e\n  \u003cli\u003eFV31-HSD High-Sensitivity GaAsP Detector\u003c\/li\u003e\n  \u003cli\u003eIX3-LHLEDC Integrated LED Transmitted Light Illuminator\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-TV1XTL Tube Lens\u003c\/li\u003e\n  \u003cli\u003eOlympus IX2-LWUCD Universal Condenser\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-SSU Substage Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus CBHIX3-CBH Control Box\u003c\/li\u003e\n  \u003cli\u003eOlympus FV31-LETD Laser Safety Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus FV30-Analog and FV30-RFACA Modules\u003c\/li\u003e\n  \u003cli\u003eOlympus FV12-ICOV Imaging Controller\u003c\/li\u003e\n  \u003cli\u003eOlympus FV31-HSU-P Scan Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus U-TBI90 Binocular Head\u003c\/li\u003e\n  \u003cli\u003eOlympus U-CMT, U-MCZ, WBN10X-H\/22 Eyepieces\u003c\/li\u003e\n  \u003cli\u003eOlympus GX-SPU, I3-TPC Control Systems\u003c\/li\u003e\n  \u003cli\u003eNosepiece: 6-Position Motorized Nosepiece\u003c\/li\u003e\n  \u003cli\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase)\u003c\/li\u003e\n  \u003cli\u003eIncluded Software Modules:\n    \u003cul\u003e\n      \u003cli\u003eFV31S-SW (Base Software – User PC Required)\u003c\/li\u003e\n      \u003cli\u003eFV31S-WELNVG (Well Navigator)\u003c\/li\u003e\n      \u003cli\u003eFV31S-VCH (Virtual Channel)\u003c\/li\u003e\n      \u003cli\u003eFV30S-PIEZO (Piezo Drive Control)\u003c\/li\u003e\n      \u003cli\u003eFV30S-MS (Multiple Area Time Lapse)\u003c\/li\u003e\n      \u003cli\u003eCS-S-DI-V* (cellSens Dimension V3)\u003c\/li\u003e\n      \u003cli\u003eCS-S-MP (Multiposition)\u003c\/li\u003e\n      \u003cli\u003eCS-S-WN (Well Plate Navigator)\u003c\/li\u003e\n      \u003cli\u003eCS-S-DE (Deconvolution)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAvailable Options\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eObjectives (Please discuss your application or preferred configuration with our team. We have a full suite of options available.)\u003c\/li\u003e\n  \u003cli\u003eStage: Motorized and Manual options available\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Incubation System\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-ZDC2 Zero Drift Compensation Unit\u003c\/li\u003e\n  \u003cli\u003eOptical Table: New and Refurbished options available\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIlluminator (Choose One):\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100w Mercury w\/ Power Supply\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: Used Metal Halide\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite 110LED System with Adapter. Includes: X-Cite 110LED, speedDIAL remote, 3mm x 1500mm Liquid Light Guide\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite mini+ System. Includes: LED head, miniCUBE controller, speedDIAL remote, Microscope Coupling Flange\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite XYLIS II, XT730S w\/1.5m LLG. Includes: X-Cite XYLIS (XT720S), speedDIAL remote, 3mm x 1500mm Liquid Light Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFV3000RS confocal scanner with galvanometer and high-speed resonant scanning\u003c\/li\u003e\n  \u003cli\u003eFV31-HSD GaAsP detector for high-sensitivity fluorescence detection\u003c\/li\u003e\n  \u003cli\u003eFV31-DF multi-position filter wheel for spectral detection\u003c\/li\u003e\n  \u003cli\u003eFive-line Coherent OBIS laser excitation: 405, 488, 514, 561, and 640 nm\u003c\/li\u003e\n  \u003cli\u003eMotorized IX83 inverted stand for fluorescence and transmitted light applications\u003c\/li\u003e\n  \u003cli\u003eIX3-LHLEDC transmitted LED illumination for phase contrast and brightfield\u003c\/li\u003e\n  \u003cli\u003eOptional IX3-ZDC2 module maintains focus for long-term live-cell imaging\u003c\/li\u003e\n  \u003cli\u003eOptional motorized stage and environmental incubation\u003c\/li\u003e\n  \u003cli\u003eIntegrated FluoView and cellSens software suite, including deconvolution and well plate navigation\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-stacks, multi-channel acquisition, multi-area time-lapse, and tiling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-resolution fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eLive-cell confocal time-lapse\u003c\/li\u003e\n  \u003cli\u003eOrganoids and tissue sections\u003c\/li\u003e\n  \u003cli\u003eHigh-speed ratiometric and FRET imaging\u003c\/li\u003e\n  \u003cli\u003eFRAP and ROI-guided photostimulation\u003c\/li\u003e\n  \u003cli\u003eZ-stack optical sectioning\u003c\/li\u003e\n  \u003cli\u003eMulti-label protein localization\u003c\/li\u003e\n  \u003cli\u003eSignal quantification and intensity tracking\u003c\/li\u003e\n  \u003cli\u003eWell plate and multi-position imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"border-collapse: collapse; width: 100%; font-size: 14px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eMicroscope Stand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOlympus IX83 P2ZF Inverted, Motorized\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eConfocal Scanner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOlympus FV3000RS with FV31-HSU-P Scan Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eScanning Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eGalvano, Resonant, Multi-area, Time-lapse, Line Scan\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eLaser Lines\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e405, 488, 514, 561, 640 nm (Coherent OBIS)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eLaser Combiner\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eCoherent FV31-MCOMB\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eDetection Module\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eFV31-HSD GaAsP Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eFilter Wheel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eFV31-DF\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eContrast Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eFluorescence, Phase Contrast, Brightfield\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eTransmitted Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eIX3-LHLEDC Integrated LED Illumination\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eFluorescence Illumination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eChoice of Mercury, Metal Halide, or X-Cite LED (see Illuminator options)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eNosepiece\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e6-Position Motorized\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eFilter Cubes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eOptical Modules\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eIX3-TV1XTL, IX2-LWUCD, IX3-SSU\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eControl Electronics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eCBHIX3-CBH, GX-SPU, I3-TPC, FV12-ICOV\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eZ Drift Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOptional, Olympus IX3-ZDC2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOptional, Motorized and Manual options available\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eObjectives\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOptional, configured to application\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eEnvironmental Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eOptical Table\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eOptional, New and Refurbished options available\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eFV31-LETD Laser Safety Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 4px 8px;\"\u003eFluoView FV31S and cellSens Dimension V3 (see Included Items for modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Olympus","offers":[{"title":"Default Title","offer_id":47504547283198,"sku":"51818","price":236500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/7860\/5310\/files\/Olympus_Fluoview_51818_1.png?v=1793764522"}],"url":"https:\/\/coastalmicroscopes.com\/collections\/fluoview-confocals.oembed","provider":"Coastal Microscopes","version":"1.0","type":"link"}