{"product_id":"leica-hcx-pl-fluotar-40x-0-75-m25-thread-size-microscope-objective-52293d","title":"Leica HCX PL Fluotar 40x\/0.75 M25 Thread Size Microscope Objective","description":"\u003ch2\u003eLeica HCX PL FLUOTAR 40x\/0.75 Objective – 506144\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eLeica HCX PL FLUOTAR 40x\/0.75\u003c\/strong\u003e is a high-quality plan fluorite microscope objective designed for fluorescence and transmitted-light microscopy. Featuring \u003cstrong\u003e40x magnification\u003c\/strong\u003e, a \u003cstrong\u003e0.75 numerical aperture\u003c\/strong\u003e, and an \u003cstrong\u003eM25 objective thread\u003c\/strong\u003e, this dry objective provides strong resolution, contrast, and light transmission for routine and advanced biological imaging applications.\n\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eCondition: Refurbished\/Used (This product has been inspected and verified to meet manufacturer specifications)\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e40x magnification\u003c\/li\u003e\n  \u003cli\u003e0.75 numerical aperture\u003c\/li\u003e\n  \u003cli\u003eHCX PL FLUOTAR plan fluorite optical design\u003c\/li\u003e\n  \u003cli\u003eDry objective requiring no immersion medium\u003c\/li\u003e\n  \u003cli\u003eInfinity-corrected optical design\u003c\/li\u003e\n  \u003cli\u003eHigh light transmission suitable for fluorescence microscopy\u003c\/li\u003e\n  \u003cli\u003ePlan correction for a flat image field\u003c\/li\u003e\n  \u003cli\u003eM25 objective mounting thread\u003c\/li\u003e\n  \u003cli\u003eDesigned for compatible Leica microscope systems\u003c\/li\u003e\n  \u003cli\u003eSuitable for fluorescence and transmitted-light imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eFluorescence microscopy\u003c\/li\u003e\n  \u003cli\u003eImmunofluorescence\u003c\/li\u003e\n  \u003cli\u003eCell and tissue imaging\u003c\/li\u003e\n  \u003cli\u003eFixed-cell microscopy\u003c\/li\u003e\n  \u003cli\u003eBrightfield microscopy\u003c\/li\u003e\n  \u003cli\u003eDIC microscopy when configured with compatible DIC components\u003c\/li\u003e\n  \u003cli\u003eHistology and pathology research\u003c\/li\u003e\n  \u003cli\u003eBiomedical and life science research\u003c\/li\u003e\n  \u003cli\u003eGeneral high-resolution laboratory microscopy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLeica Microsystems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHCX PL FLUOTAR 40x\/0.75\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e506144\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eObjective Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePlan Fluorite\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOptical Series\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHCX PL FLUOTAR\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMagnification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e40x\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNumerical Aperture (NA)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.75\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eImmersion Medium\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDry \/ Air\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOptical Correction\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePlan Fluorite\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOptical System\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eInfinity-corrected\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eObjective Thread\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eM25\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFluorescence Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eTransmitted-Light Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eDIC Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConfiguration dependent; requires compatible DIC components\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMicroscope Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCompatible Leica microscope systems using M25 objective threads\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePrimary Applications\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFluorescence, transmitted-light, cell, tissue, and general biological microscopy\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Pacific Northwest Research Institute","offers":[{"title":"Default Title","offer_id":48737342947582,"sku":"52293d","price":900.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/coastalmicroscopes.com\/products\/leica-hcx-pl-fluotar-40x-0-75-m25-thread-size-microscope-objective-52293d","provider":"Coastal Microscopes","version":"1.0","type":"link"}