{"product_id":"leica-tcs-sp8-laser-confocal-w-dmi8-inverted-phase-contrast-fluorescence-confocal-52252","title":"Leica TCS SP8 Laser Confocal w\/ DMI8 Inverted Phase Contrast Fluorescence  Confocal","description":"\u003ch2\u003eLeica DMi8 Automated Inverted Fluorescence Microscope with TCS SP8 Laser Scanning Confocal System (Used)\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eLeica DMi8 with TCS SP8 Laser Scanning Confocal System\u003c\/strong\u003e combines a fully motorized inverted research microscope with Leica's modular spectral confocal imaging platform for advanced fluorescence, live-cell, optical sectioning, and multidimensional microscopy. The DMi8 provides motorized control of focus, nosepiece, condenser, fluorescence turret, and compatible stage configurations, while the TCS SP8 adds high-resolution confocal imaging, spectral detection, Z-stack acquisition, 3D imaging, and configurable multichannel fluorescence workflows.\n\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eCondition: Refurbished\/Used (This product has been inspected and verified to meet manufacturer specifications)\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003ch3\u003eIncluded Items\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eLeica DMi8 Inverted Microscope Stand\u003c\/li\u003e\n  \u003cli\u003eLeica TCS SP8 Laser Scanning Confocal Scan Head\u003c\/li\u003e\n  \u003cli\u003eSP8 Confocal Detector System\u003c\/li\u003e\n  \u003cli\u003eBinocular Viewing Head with Camera Port\u003c\/li\u003e\n  \u003cli\u003eMotorized Focus Drive\u003c\/li\u003e\n  \u003cli\u003eMotorized 6-Position Nosepiece\u003c\/li\u003e\n  \u003cli\u003eMotorized Condenser\u003c\/li\u003e\n  \u003cli\u003eMotorized Fluorescence Filter Cube Turret\u003c\/li\u003e\n  \u003cli\u003ePhase Contrast Slider\u003c\/li\u003e\n  \u003cli\u003eFluorescence Illuminator: 100w Mercury with Power Supply\u003c\/li\u003e\n  \u003cli\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase)\u003c\/li\u003e\n  \u003cli\u003eSP8 Laser Source \/ Laser Module\u003c\/li\u003e\n  \u003cli\u003ePower Supplies and Cabling\u003c\/li\u003e\n  \u003cli\u003eControl Computer configured for microscope and confocal operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCustomization and Optional Upgrades\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n    \u003cstrong\u003eObjectives:\u003c\/strong\u003e Please discuss your application or preferred configuration with our team. We have a full suite of options available.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eStage:\u003c\/strong\u003e Motorized and Manual options available.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eNosepiece:\u003c\/strong\u003e Motorized, 6-position.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSP8 Laser Configuration:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eLaser excitation configuration can be customized to the application\u003c\/li\u003e\n      \u003cli\u003eSolid-state laser configurations available\u003c\/li\u003e\n      \u003cli\u003eWhite Light Laser configurations available on compatible SP8 systems\u003c\/li\u003e\n      \u003cli\u003eExcitation wavelengths depend on the installed laser configuration\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSP8 Detection Options:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eSpectral confocal detection\u003c\/li\u003e\n      \u003cli\u003ePMT detector configurations available\u003c\/li\u003e\n      \u003cli\u003eLeica HyD detector configurations available\u003c\/li\u003e\n      \u003cli\u003eMultichannel fluorescence detection configurations available\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSP8 Scanning Options:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eGalvanometric point scanning\u003c\/li\u003e\n      \u003cli\u003eResonant scanning available on compatible configurations\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eIlluminator (Choose One):\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003e100w Mercury w\/ Power Supply\u003c\/li\u003e\n      \u003cli\u003eUpgrade to: Used Metal Halide\u003c\/li\u003e\n      \u003cli\u003eUpgrade to: New X-Cite 110LED System with Adapter X-Cite 110LED, speedDIAL remote, 3mm x 1500mm Liquid Light Guide\u003c\/li\u003e\n      \u003cli\u003eUpgrade to: New X-Cite mini + System Includes: LED head, miniCUBE controller, speedDIAL remote; Includes: LED head, miniCUBE controller, speedDIAL remote, Microscope Coupling Flange\u003c\/li\u003e\n      \u003cli\u003eUpgrade to: New X-Cite XYLIS II, XT730S w\/1.5m LLG, Includes: X-Cite XYLIS (XT720S), speedDIAL remote, 3mm x 1500mm Liquid Light Guide\u003c\/li\u003e\n      \u003cli\u003eNew or Used Leica Illuminator\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eCameras (sCMOS, EMCCD, CCD, CMOS):\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eNew or Used Hamamatsu\u003c\/li\u003e\n      \u003cli\u003eNew or Used Tucsen\u003c\/li\u003e\n      \u003cli\u003eNew or Used PCO\u003c\/li\u003e\n      \u003cli\u003eNew or Used Teledyne Photometrics\u003c\/li\u003e\n      \u003cli\u003eNew or Used Teledyne Lumenera\u003c\/li\u003e\n      \u003cli\u003eNew or Used Leica Camera\u003c\/li\u003e\n      \u003cli\u003eUsed Andor\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eFilter Cubes:\u003c\/strong\u003e (3) Filter Cubes of your choice (Additional Cubes Available for purchase).\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eContrast Methods:\u003c\/strong\u003e Phase contrast, brightfield, widefield fluorescence, and confocal fluorescence configurations available. Additional contrast methods may be configured with compatible components.\n  \u003c\/li\u003e\n\n  \u003cli\u003e\n    \u003cstrong\u003eSoftware:\u003c\/strong\u003e Leica LAS X configurations available for microscope control, confocal acquisition, Z-stacking, time-lapse imaging, multidimensional acquisition, visualization, and analysis. Training and method development available.\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eIntegrated Leica DMi8 inverted microscope and TCS SP8 laser scanning confocal platform\u003c\/li\u003e\n  \u003cli\u003eFully motorized inverted research microscope configuration\u003c\/li\u003e\n  \u003cli\u003eMotorized Z-focus, nosepiece, condenser, and fluorescence turret\u003c\/li\u003e\n  \u003cli\u003ePoint-scanning confocal imaging for optical sectioning and high-contrast fluorescence acquisition\u003c\/li\u003e\n  \u003cli\u003eSpectral confocal detection architecture\u003c\/li\u003e\n  \u003cli\u003eConfigurable PMT and Leica HyD detector options\u003c\/li\u003e\n  \u003cli\u003eConfigurable laser excitation for multicolor fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eWhite Light Laser available on compatible SP8 configurations\u003c\/li\u003e\n  \u003cli\u003eStandard galvanometric scanning with resonant scanning available on compatible configurations\u003c\/li\u003e\n  \u003cli\u003eSupports multichannel fluorescence acquisition\u003c\/li\u003e\n  \u003cli\u003eSupports optical sectioning and Z-stack acquisition\u003c\/li\u003e\n  \u003cli\u003eSupports 3D fluorescence imaging and reconstruction workflows\u003c\/li\u003e\n  \u003cli\u003eSupports time-lapse and multidimensional imaging\u003c\/li\u003e\n  \u003cli\u003eInverted microscope architecture well suited for dishes, flasks, chamber slides, and multi-well plates\u003c\/li\u003e\n  \u003cli\u003eWell suited for live-cell and multi-position imaging workflows\u003c\/li\u003e\n  \u003cli\u003eModular architecture allows the system to be configured for application-specific research requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eLaser scanning confocal microscopy\u003c\/li\u003e\n  \u003cli\u003eLive-cell fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eMulticolor fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eOptical sectioning\u003c\/li\u003e\n  \u003cli\u003eZ-stack acquisition\u003c\/li\u003e\n  \u003cli\u003e3D fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eTime-lapse microscopy\u003c\/li\u003e\n  \u003cli\u003eMulti-position imaging\u003c\/li\u003e\n  \u003cli\u003ePhase contrast imaging\u003c\/li\u003e\n  \u003cli\u003eImmunofluorescence\u003c\/li\u003e\n  \u003cli\u003eCell culture imaging\u003c\/li\u003e\n  \u003cli\u003eStem cell research\u003c\/li\u003e\n  \u003cli\u003eOncology and cancer research\u003c\/li\u003e\n  \u003cli\u003eDrug discovery research\u003c\/li\u003e\n  \u003cli\u003eNeuroscience\u003c\/li\u003e\n  \u003cli\u003eDevelopmental biology\u003c\/li\u003e\n  \u003cli\u003eColocalization studies\u003c\/li\u003e\n  \u003cli\u003eQuantitative fluorescence microscopy\u003c\/li\u003e\n  \u003cli\u003eHigh-content and automated imaging workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLeica Microsystems\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMicroscope Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eDMi8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eConfocal Model\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eTCS SP8\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSystem Type\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAutomated Inverted Laser Scanning Confocal Fluorescence Microscope\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMicroscope Orientation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eInverted\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eScanning Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePoint-Scanning Confocal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eScanner Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eGalvanometric; resonant scanning available depending on SP8 configuration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eConfocal Detection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSpectral detection with PMT and\/or HyD detector configurations available\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eLaser Excitation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConfiguration dependent; solid-state and White Light Laser configurations available\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eWhite Light Laser\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAvailable on compatible SP8 configurations\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFocus Drive\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMotorized\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNosepiece\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMotorized, 6-position\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eObjectives\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePlease discuss your application or preferred configuration with our team. We have a full suite of options available.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eStage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMotorized and Manual options available.\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCondenser\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMotorized ELWD condenser; phase contrast configuration available\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFluorescence Turret\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMotorized\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFilter Cubes\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eWidefield Fluorescence Illumination\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e100w Mercury standard; Metal Halide and LED upgrade configurations available\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eContrast Methods\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eConfocal Fluorescence, Widefield Fluorescence, Phase Contrast, and Brightfield; additional methods configuration dependent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOptical Sectioning\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eMultichannel Imaging\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eZ-Stack Imaging\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003e3D Imaging\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eTime-Lapse Imaging\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eYes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLeica LAS X; software configuration depends on installed SP8 hardware and imaging requirements\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eStandard AC; required power supplies and cords included\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e6-month parts and labor warranty\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Pacific Northwest Research Institute","offers":[{"title":"Default Title","offer_id":48738296758526,"sku":"52252","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/coastalmicroscopes.com\/products\/leica-tcs-sp8-laser-confocal-w-dmi8-inverted-phase-contrast-fluorescence-confocal-52252","provider":"Coastal Microscopes","version":"1.0","type":"link"}