{"product_id":"okolab-warm-ito-glass-plate-with-heated-metal-frame-for-nikon-stage-t-ti-sr-and-ti-sp-flat-108-mm-diameter-environmental-control-oko-h601-nikon-ti-sr-glass-frame","title":"Okolab Warm ITO glass plate with heated metal frame for Nikon stage T\/Ti-SR and Ti-SP. Flat - 108 mm diameter Environmental Control","description":"\u003ch2\u003eOkolab H601‑NIKON‑TI‑SR‑GLASS\/FRAME ITO Glass Plate with Heated Frame | Dual‑Channel Ø108 mm Heating Plate\u003c\/h2\u003e\n\u003cp\u003eThe Okolab \u003cstrong\u003eH601‑NIKON‑TI‑SR‑GLASS\/FRAME\u003c\/strong\u003e is a precision dual-channel heated plate tailored for Nikon inverted microscopes equipped with T\/Ti‑SR and Ti‑SP stages. It combines a transparent ITO-coated Dragontrail™ glass surface and a heated aluminum frame to deliver exceptional thermal uniformity and optical clarity.\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCondition: New with Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003ch3\u003eIncluded Items\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOne H601‑NIKON‑TI‑SR‑GLASS\/FRAME heated plate (factory‑sealed, brand new)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFlush flush-mounted to Nikon T\/Ti-SR and Ti-SP stages for seamless integration :contentReference[oaicite:0]{index=0}\u003c\/li\u003e\n  \u003cli\u003eDual-channel heating controls both ITO glass and aluminum frame independently, ensuring maximum temperature uniformity :contentReference[oaicite:1]{index=1}\u003c\/li\u003e\n  \u003cli\u003eOperating range from ambient to 60 °C with ±0.3 °C specimen accuracy; surface sensor–regulated :contentReference[oaicite:2]{index=2}\u003c\/li\u003e\n  \u003cli\u003eDragontrail™ glass is 0.5 mm thick, anti-scratch, anti-fingerprint, and chemically strengthened :contentReference[oaicite:3]{index=3}\u003c\/li\u003e\n  \u003cli\u003eReinforced aluminum framing ensures rigidity and durability\u003c\/li\u003e\n  \u003cli\u003eProtected by a 10-year warranty on glass damage :contentReference[oaicite:4]{index=4}\u003c\/li\u003e\n  \u003cli\u003eRequires H401‑T‑CONTROLLER (dual-channel) or H401‑T‑PENNY for operation :contentReference[oaicite:5]{index=5}\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLive-cell and time-lapse imaging on Nikon inverted microscope systems\u003c\/li\u003e\n  \u003cli\u003eOil-immersion and high-resolution microscopy requiring stable, precise thermal conditions\u003c\/li\u003e\n  \u003cli\u003ePerfusion and environmental control workflows supported by dual heating zones\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"5\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eH601‑NIKON‑TI‑SR‑GLASS\/FRAME\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStage Compatibility\u003c\/td\u003e\n\u003ctd\u003eNikon T\/Ti‑SR and Ti‑SP stages\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTotal Diameter\u003c\/td\u003e\n\u003ctd\u003eApprox. 108 mm (fits stage opening)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eGlass Material\u003c\/td\u003e\n\u003ctd\u003eITO-coated Dragontrail™ glass, 0.5 mm thick\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eHeating Channels\u003c\/td\u003e\n\u003ctd\u003eDual-channel: glass + frame\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSpecimen Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eController Required\u003c\/td\u003e\n\u003ctd\u003eH401‑T‑CONTROLLER (dual‑channel) or H401‑T‑PENNY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10-year glass damage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew with Manufacturer Warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Okolab","offers":[{"title":"Default Title","offer_id":46611615711486,"sku":"OKO-H601-NIKON-TI-SR-GLASS\/FRAME","price":1247.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/7860\/5310\/files\/H601-NIKON-TI-SR-GLASS_FRAME-420x280_02-Photoroom_5beeb4d2-6da7-49d1-b27f-a24269d41083.png?v=1776966193","url":"https:\/\/coastalmicroscopes.com\/products\/okolab-warm-ito-glass-plate-with-heated-metal-frame-for-nikon-stage-t-ti-sr-and-ti-sp-flat-108-mm-diameter-environmental-control-oko-h601-nikon-ti-sr-glass-frame","provider":"Coastal Microscopes","version":"1.0","type":"link"}