{"product_id":"olympus-fluoview-fv3000-laser-scanning-confocal-w-ix83-p2zf-inverted-phase-contrast-fluorescence-motorized-w-optional-zero-drift-confocal-51818","title":"Olympus Fluoview FV3000 Laser Scanning Confocal w\/IX83 P2ZF Inverted Phase Contrast Fluorescence Motorized w\/ optional Zero Drift Confocal","description":"\u003ch2\u003eOlympus FV3000 Laser Scanning Confocal with IX83 P2ZF Inverted Microscope – Refurbished\u003c\/h2\u003e\n\u003cp\u003eThe Olympus FV3000 Confocal system combined with the IX83 P2ZF inverted motorized stand offers high-speed, multi-channel fluorescence imaging. Designed for advanced research applications, this system supports optical sectioning, live-cell time-lapse, and high-resolution imaging with integrated modules for laser control, signal detection, and system stability.\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\u003cp\u003eRefurbished\/Used (This product has been inspected and verified to meet manufacturer specifications)\u003c\/p\u003e\n\n\u003ch3\u003eIncluded Items\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOlympus FV3000 Confocal Scanner Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus IX83 P2ZF Inverted Microscope, Motorized, Phase Contrast, Fluorescence\u003c\/li\u003e\n  \u003cli\u003eCoherent OBIS Lasers:\n    \u003cul\u003e\n      \u003cli\u003e405 nm (1306092)\u003c\/li\u003e\n      \u003cli\u003e488 nm (OBIS 488-20 LS CW 1306398)\u003c\/li\u003e\n      \u003cli\u003e514 nm (1306091)\u003c\/li\u003e\n      \u003cli\u003e561 nm (OBIS 561-20 LS CW 1306400)\u003c\/li\u003e\n      \u003cli\u003e640 nm (1306090)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eCoherent FV31-MCOMB Laser Combiner\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFV31-DF\u003c\/strong\u003e Spectral Detection Filter Wheel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFV31-HSD\u003c\/strong\u003e High-Sensitivity GaAsP Detector\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIX3-LHLEDC\u003c\/strong\u003e Integrated LED Transmitted Light Illuminator\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-ZDC2 Zero Drift Compensation Unit (Optional)\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-TV1XTL Tube Lens\u003c\/li\u003e\n  \u003cli\u003eOlympus IX2-LWUCD Universal Condenser\u003c\/li\u003e\n  \u003cli\u003eOlympus IX3-SSU Substage Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus CBHIX3-CBH Control Box\u003c\/li\u003e\n  \u003cli\u003eOlympus FV31-LETD Laser Safety Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus FV30-Analog and FV30-RFACA Modules\u003c\/li\u003e\n  \u003cli\u003eOlympus FV12-ICOV Imaging Controller\u003c\/li\u003e\n  \u003cli\u003eOlympus FV31-HSU-P Scan Unit\u003c\/li\u003e\n  \u003cli\u003eOlympus U-TBI90 Binocular Head\u003c\/li\u003e\n  \u003cli\u003eOlympus U-CMT, U-MCZ, WBN10X-H\/22 Eyepieces\u003c\/li\u003e\n  \u003cli\u003eOlympus GX-SPU, I3-TPC Control Systems\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIncluded Software Modules:\u003c\/strong\u003e\n    \u003cul\u003e\n      \u003cli\u003eFV31S-SW (Base Software – User PC Required)\u003c\/li\u003e\n      \u003cli\u003eFV31S-WELNVG (Well Navigator)\u003c\/li\u003e\n      \u003cli\u003eFV31S-VCH (Virtual Channel)\u003c\/li\u003e\n      \u003cli\u003eFV30S-PIEZO (Piezo Drive Control)\u003c\/li\u003e\n      \u003cli\u003eFV30S-MS (Multiple Area Time Lapse)\u003c\/li\u003e\n      \u003cli\u003eCS-S-DI-V* (cellSens Dimension V3)\u003c\/li\u003e\n      \u003cli\u003eCS-S-MP (Multiposition)\u003c\/li\u003e\n      \u003cli\u003eCS-S-WN (Well Plate Navigator)\u003c\/li\u003e\n      \u003cli\u003eCS-S-DE (Deconvolution)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFV31-DF\u003c\/strong\u003e: Multi-position filter wheel for spectral detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFV31-HSD\u003c\/strong\u003e: GaAsP detector for high-sensitivity fluorescence detection\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIX3-LHLEDC\u003c\/strong\u003e: Transmitted light LED illumination for DIC and phase\u003c\/li\u003e\n  \u003cli\u003eMotorized IX83 inverted stand for fluorescence and transmitted light applications\u003c\/li\u003e\n  \u003cli\u003eOptional IX3-ZDC2 module maintains focus for long-term live-cell imaging\u003c\/li\u003e\n  \u003cli\u003eIntegrated Olympus software suite and hardware modules\u003c\/li\u003e\n  \u003cli\u003eCompatible with Z-stacks, multi-channel acquisition, and time-lapse imaging\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-resolution fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eLive-cell confocal time-lapse\u003c\/li\u003e\n  \u003cli\u003eZ-stack optical sectioning\u003c\/li\u003e\n  \u003cli\u003eMulti-label protein localization\u003c\/li\u003e\n  \u003cli\u003eSignal quantification and intensity tracking\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"6\" cellspacing=\"0\"\u003e\n  \u003ctr\u003e\n\u003cth\u003eComponent\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMicroscope Stand\u003c\/td\u003e\n\u003ctd\u003eOlympus IX83 P2ZF Inverted, Motorized\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConfocal Scanner\u003c\/td\u003e\n\u003ctd\u003eOlympus FV3000\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eScanning Modes\u003c\/td\u003e\n\u003ctd\u003eGalvano scanning, Multi-area, Time-lapse, Line Scan\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eZ Drift Compensation\u003c\/td\u003e\n\u003ctd\u003eOlympus IX3-ZDC2 (Optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eStage\u003c\/td\u003e\n\u003ctd\u003eMotorized and Manual options available\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFilter Cubes\u003c\/td\u003e\n\u003ctd\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLaser Lines\u003c\/td\u003e\n\u003ctd\u003e405, 488, 514, 561, 640 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLaser Combiner\u003c\/td\u003e\n\u003ctd\u003eCoherent FV31-MCOMB\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDetection Module\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eFV31-HSD\u003c\/strong\u003e GaAsP Detector\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eFilter Wheel\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eFV31-DF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransmitted Light\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eIX3-LHLEDC\u003c\/strong\u003e Integrated LED Illumination\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eOptical Modules\u003c\/td\u003e\n\u003ctd\u003eIX3-TV1XTL, IX2-LWUCD, IX3-SSU\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eControl Electronics\u003c\/td\u003e\n\u003ctd\u003eCBHIX3-CBH, GX-SPU, I3-TPC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSafety\u003c\/td\u003e\n\u003ctd\u003eFV31-LETD Laser Safety Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eSee Included Items section for full list of modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eObjectives\u003c\/h3\u003e\n\u003cp\u003e(Please discuss your application or preferred configuration with our team. We have a full suite of options available.)\u003c\/p\u003e\n\n\u003ch3\u003eStage\u003c\/h3\u003e\n\u003cp\u003eMotorized and Manual options available.\u003c\/p\u003e\n\n\u003ch3\u003eFilter Cubes\u003c\/h3\u003e\n\u003cp\u003e(3) Filter Cubes of your choice (Additional Cubes Available for purchase).\u003c\/p\u003e\n\n\u003ch3\u003eIlluminator (Choose One):\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e100w Mercury w\/ Power Supply\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: Used Metal Halide\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite 110LED System with Adapter X-Cite 110LED, speedDIAL remote, 3mm x 1500mm Liquid Light Guide\u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite mini + System\u003cbr\u003e\n    Includes: – LED head, miniCUBE controller, speedDIAL remote, – Microscope Coupling Flange\n  \u003c\/li\u003e\n  \u003cli\u003eUpgrade to: New X-Cite XYLIS II, XT730S w\/1.5m LLG\u003cbr\u003e\n    Includes: – X-Cite XYLIS (XT720S), speedDIAL remote, 3mm x 1500mm Liquid Light Guide\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Liquidity Services","offers":[{"title":"Default Title","offer_id":47504547283198,"sku":"51818","price":240000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0693\/7860\/5310\/files\/Olympus_Fluoview_51818_1.png?v=1774964703","url":"https:\/\/coastalmicroscopes.com\/products\/olympus-fluoview-fv3000-laser-scanning-confocal-w-ix83-p2zf-inverted-phase-contrast-fluorescence-motorized-w-optional-zero-drift-confocal-51818","provider":"Coastal Microscopes","version":"1.0","type":"link"}