{"product_id":"zeiss-colibri-7-fr-r-g-y-bv-uv-microscope-illuminator-50060h","title":"Zeiss Colibri 7 FR-R(G\/Y)BV-UV Microscope Illuminator","description":"\u003ch2\u003eZEISS Colibri 7 FR-R[G\/Y]BV-UV Microscope Illuminator – 423052-9770-0000\u003c\/h2\u003e\n\n\u003cp\u003e\n  The \u003cstrong\u003eZEISS Colibri 7 FR-R[G\/Y]BV-UV\u003c\/strong\u003e is a seven-channel solid-state LED fluorescence illumination system designed for demanding fluorescence microscopy applications. Its broad excitation coverage from UV through far-red supports a wide range of common fluorophores, while individually controlled LED channels, rapid switching, and stabilized output provide reproducible illumination for multichannel fluorescence imaging.\n\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003eCondition: Refurbished\/Used (This product has been inspected and verified to meet manufacturer specifications)\u003c\/strong\u003e\n\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eSeven-channel LED fluorescence illumination spanning UV through far-red wavelengths.\u003c\/li\u003e\n  \u003cli\u003eExcitation lines at \u003cstrong\u003e735, 630, 590, 555, 475, 430, and 385 nm\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eSupports fluorophores across UV, violet, blue, green, yellow, red, and far-red excitation ranges.\u003c\/li\u003e\n  \u003cli\u003eIndividual control of excitation lines for flexible multichannel fluorescence imaging.\u003c\/li\u003e\n  \u003cli\u003eLinearized intensity regulation from \u003cstrong\u003e1–100% in 1% increments\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eIntegrated motorized, switchable excitation filters.\u003c\/li\u003e\n  \u003cli\u003eReal-time brightness stabilization helps maintain consistent illumination during image acquisition.\u003c\/li\u003e\n  \u003cli\u003eRapid wavelength switching without the warm-up and cool-down requirements associated with traditional arc-lamp illumination.\u003c\/li\u003e\n  \u003cli\u003eRated LED lifetime of \u003cstrong\u003e15,000 hours per LED line\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003eCompatible with supported ZEISS microscope systems and ZEN Imaging Software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMultichannel fluorescence microscopy\u003c\/li\u003e\n  \u003cli\u003eLive-cell fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eFixed-cell fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eImmunofluorescence\u003c\/li\u003e\n  \u003cli\u003eFISH applications\u003c\/li\u003e\n  \u003cli\u003eDAPI\/Hoechst nuclear staining\u003c\/li\u003e\n  \u003cli\u003eGFP\/FITC fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eCy3\/TRITC fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003emCherry\/Alexa Fluor 568 imaging\u003c\/li\u003e\n  \u003cli\u003eCy5 and related far-red fluorescence imaging\u003c\/li\u003e\n  \u003cli\u003eCy7 and other extended far-red applications\u003c\/li\u003e\n  \u003cli\u003eAutomated and time-lapse fluorescence microscopy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eZEISS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eColibri 7 Solid-State Fluorescence Light Source\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eModel \/ Configuration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFR-R[G\/Y]BV-UV\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e423052-9770-0000\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eIllumination Technology\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSolid-state LED\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eNumber of Excitation Lines\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e7\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eFar-Red (FR)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e735 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eRed (R)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e630 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eYellow (Y)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e590 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eGreen (G)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e555 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBlue (B)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e475 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eViolet (V)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e430 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eUV\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e385 nm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eOverall Excitation Coverage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUV through far-red\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eIntensity Regulation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLinearized, 1–100% in 1% increments\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eExcitation Filters\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eIntegrated, motorized and switchable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eBrightness Stabilization\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eReal-time stabilization\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eLED Lifetime\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e15,000 hours per LED line\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eSoftware Control\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eSupported through ZEISS ZEN Imaging Software\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eAdditional Control Options\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eZEISS control panel \/ LED Trigger Box, system dependent\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eLight Source Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e167 × 183 × 103 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003eLight Source Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eUp to 1,900 g\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e\u003cstrong\u003ePrimary Application\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFluorescence microscopy\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Zeiss","offers":[{"title":"Default Title","offer_id":46287903457534,"sku":"50060h","price":7250.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/coastalmicroscopes.com\/products\/zeiss-colibri-7-fr-r-g-y-bv-uv-microscope-illuminator-50060h","provider":"Coastal Microscopes","version":"1.0","type":"link"}