{"product_id":"zeiss-shutter-high-speed-external-shutter-52165u","title":"Zeiss Shutter High Speed, external Shutter","description":"\u003ch2\u003eZeiss High-Speed Shutter (Model 423627-9901)\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong\u003eZeiss High-Speed Shutter\u003c\/strong\u003e (Model \u003cstrong\u003e423627-9901\u003c\/strong\u003e) is a \u003cstrong\u003eprecision optical shutter system\u003c\/strong\u003e designed for \u003cstrong\u003efast and reliable light control in fluorescence microscopy and high-speed imaging applications\u003c\/strong\u003e. Featuring \u003cstrong\u003erapid actuation, seamless integration with Zeiss imaging systems, and precise exposure timing\u003c\/strong\u003e, this high-speed shutter ensures \u003cstrong\u003eaccurate light control for time-sensitive fluorescence experiments\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCondition\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRefurbished\/Used\u003c\/strong\u003e (This product has been inspected and verified to meet manufacturer specifications.)\u003c\/p\u003e\n\n\u003ch3\u003eIncluded Items\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eZeiss High-Speed Shutter\u003c\/strong\u003e (Model \u003cstrong\u003e423627-9901\u003c\/strong\u003e)\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Actuation System\u003c\/strong\u003e – Ensures precise, rapid light control for fluorescence microscopy\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeamless Zeiss Microscope Integration\u003c\/strong\u003e – Compatible with Axio Observer, Axiovert, and other Zeiss imaging platforms\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eElectronic Shutter Control Interface\u003c\/strong\u003e – Provides synchronized operation with imaging software\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUSB \u0026amp; External Trigger Connectivity\u003c\/strong\u003e – Allows for remote activation and automated workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUltra-Fast Shutter Speed\u003c\/strong\u003e – Enables rapid light exposure control for fluorescence imaging\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSeamless Zeiss Microscope Compatibility\u003c\/strong\u003e – Fully integrates with Zeiss imaging systems\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrecise Light Control\u003c\/strong\u003e – Minimizes photobleaching and optimizes exposure times\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExternal Trigger Support\u003c\/strong\u003e – Compatible with TTL signals for automated control\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDurable \u0026amp; Low-Maintenance Design\u003c\/strong\u003e – Engineered for long-term use in research environments\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact \u0026amp; Modular Setup\u003c\/strong\u003e – Easily integrates into existing microscopy workflows\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003eFluorescence Microscopy with Controlled Light Exposure\u003c\/li\u003e\n    \u003cli\u003eHigh-Speed Time-Lapse Imaging\u003c\/li\u003e\n    \u003cli\u003ePhotoactivation \u0026amp; Photobleaching Studies\u003c\/li\u003e\n    \u003cli\u003eLive-Cell Imaging with Minimal Light Exposure\u003c\/li\u003e\n    \u003cli\u003eNeuroscience \u0026amp; Optogenetics Research\u003c\/li\u003e\n    \u003cli\u003eAutomated Screening \u0026amp; Image Acquisition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n    \u003ctr\u003e\n        \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003cth\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eHigh-Speed Optical Shutter\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003e423627-9901\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eShutter Speed\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eHigh-Speed Actuation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eIntegration\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eCompatible with Zeiss Axio Observer, Axiovert, and Other Zeiss Microscopes\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eControl Interface\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eElectronic Interface with External Trigger Support\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eUSB \u0026amp; TTL External Trigger Input\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd\u003e\u003cstrong\u003eSoftware Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd\u003eZeiss Zen Imaging Software \u0026amp; Third-Party Automation Tools\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cp\u003e\u003cstrong\u003eConfiguration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Coastal Microscopes","offers":[{"title":"Default Title","offer_id":48285759209726,"sku":"52165u","price":1500.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/coastalmicroscopes.com\/products\/zeiss-shutter-high-speed-external-shutter-52165u","provider":"Coastal Microscopes","version":"1.0","type":"link"}