Skip to product information
1 of 6

SKU: PRODUCT ID:51818

Olympus Fluoview FV3000 Laser Scanning Confocal w/IX83 P2ZF Inverted Phase Contrast Fluorescence Motorized w/ optional Zero Drift Confocal

Olympus Fluoview FV3000 Laser Scanning Confocal w/IX83 P2ZF Inverted Phase Contrast Fluorescence Motorized w/ optional Zero Drift Confocal

Regular price $240,000.00 USD
Regular price Sale price $240,000.00 USD
Sale Sold out
Shipping calculated at checkout.

Olympus FV3000RS Laser Scanning Confocal with IX83 P2ZF Inverted Microscope – Refurbished

The Olympus FV3000RS Confocal system, combined with the IX83 P2ZF inverted motorized stand, offers high-speed, multi-channel fluorescence imaging with both galvanometer and resonant scanning. Designed for advanced research applications, this system supports optical sectioning, live-cell time-lapse, and high-resolution imaging with integrated modules for laser control, signal detection, and system stability.

Condition

Condition: Refurbished/Used (This product has been inspected and verified to meet manufacturer specifications)

Included Items

  • Olympus FV3000 Confocal Scanner Unit
  • High Speed Resonant Scanner
  • Olympus IX83 P2ZF Inverted Microscope, Motorized, Phase Contrast, Fluorescence
  • Coherent OBIS Lasers:
    • 405 nm (1306092)
    • 488 nm (OBIS 488-20 LS CW 1306398)
    • 514 nm (1306091)
    • 561 nm (OBIS 561-20 LS CW 1306400)
    • 640 nm (1306090)
  • Coherent FV31-MCOMB Laser Combiner
  • FV31-DF Spectral Detection Filter Wheel
  • FV31-HSD High-Sensitivity GaAsP Detector
  • IX3-LHLEDC Integrated LED Transmitted Light Illuminator
  • Olympus IX3-TV1XTL Tube Lens
  • Olympus IX2-LWUCD Universal Condenser
  • Olympus IX3-SSU Substage Unit
  • Olympus CBHIX3-CBH Control Box
  • Olympus FV31-LETD Laser Safety Unit
  • Olympus FV30-Analog and FV30-RFACA Modules
  • Olympus FV12-ICOV Imaging Controller
  • Olympus FV31-HSU-P Scan Unit
  • Olympus U-TBI90 Binocular Head
  • Olympus U-CMT, U-MCZ, WBN10X-H/22 Eyepieces
  • Olympus GX-SPU, I3-TPC Control Systems
  • Nosepiece: 6-Position Motorized Nosepiece
  • (3) Filter Cubes of your choice (Additional Cubes Available for purchase)
  • Included Software Modules:
    • FV31S-SW (Base Software – User PC Required)
    • FV31S-WELNVG (Well Navigator)
    • FV31S-VCH (Virtual Channel)
    • FV30S-PIEZO (Piezo Drive Control)
    • FV30S-MS (Multiple Area Time Lapse)
    • CS-S-DI-V* (cellSens Dimension V3)
    • CS-S-MP (Multiposition)
    • CS-S-WN (Well Plate Navigator)
    • CS-S-DE (Deconvolution)

Available Options

  • Objectives (Please discuss your application or preferred configuration with our team. We have a full suite of options available.)
  • Stage: Motorized and Manual options available
  • Environmental Incubation System
  • Olympus IX3-ZDC2 Zero Drift Compensation Unit
  • Optical Table: New and Refurbished options available

Illuminator (Choose One):

  • 100w Mercury w/ Power Supply
  • Upgrade to: Used Metal Halide
  • Upgrade to: New X-Cite 110LED System with Adapter. Includes: X-Cite 110LED, speedDIAL remote, 3mm x 1500mm Liquid Light Guide
  • Upgrade to: New X-Cite mini+ System. Includes: LED head, miniCUBE controller, speedDIAL remote, Microscope Coupling Flange
  • Upgrade to: New X-Cite XYLIS II, XT730S w/1.5m LLG. Includes: X-Cite XYLIS (XT720S), speedDIAL remote, 3mm x 1500mm Liquid Light Guide

Key Features

  • FV3000RS confocal scanner with galvanometer and high-speed resonant scanning
  • FV31-HSD GaAsP detector for high-sensitivity fluorescence detection
  • FV31-DF multi-position filter wheel for spectral detection
  • Five-line Coherent OBIS laser excitation: 405, 488, 514, 561, and 640 nm
  • Motorized IX83 inverted stand for fluorescence and transmitted light applications
  • IX3-LHLEDC transmitted LED illumination for phase contrast and brightfield
  • Optional IX3-ZDC2 module maintains focus for long-term live-cell imaging
  • Optional motorized stage and environmental incubation
  • Integrated FluoView and cellSens software suite, including deconvolution and well plate navigation
  • Compatible with Z-stacks, multi-channel acquisition, multi-area time-lapse, and tiling

Applications

  • High-resolution fluorescence imaging
  • Live-cell confocal time-lapse
  • Organoids and tissue sections
  • High-speed ratiometric and FRET imaging
  • FRAP and ROI-guided photostimulation
  • Z-stack optical sectioning
  • Multi-label protein localization
  • Signal quantification and intensity tracking
  • Well plate and multi-position imaging

Specifications

Microscope Stand Olympus IX83 P2ZF Inverted, Motorized
Confocal Scanner Olympus FV3000RS with FV31-HSU-P Scan Unit
Scanning Modes Galvano, Resonant, Multi-area, Time-lapse, Line Scan
Laser Lines 405, 488, 514, 561, 640 nm (Coherent OBIS)
Laser Combiner Coherent FV31-MCOMB
Detection Module FV31-HSD GaAsP Detector
Filter Wheel FV31-DF
Contrast Methods Fluorescence, Phase Contrast, Brightfield
Transmitted Light IX3-LHLEDC Integrated LED Illumination
Fluorescence Illumination Choice of Mercury, Metal Halide, or X-Cite LED (see Illuminator options)
Nosepiece 6-Position Motorized
Filter Cubes (3) Filter Cubes of your choice (Additional Cubes Available for purchase)
Optical Modules IX3-TV1XTL, IX2-LWUCD, IX3-SSU
Control Electronics CBHIX3-CBH, GX-SPU, I3-TPC, FV12-ICOV
Z Drift Compensation Optional, Olympus IX3-ZDC2
Stage Optional, Motorized and Manual options available
Objectives Optional, configured to application
Environmental Control Optional
Optical Table Optional, New and Refurbished options available
Safety FV31-LETD Laser Safety Unit
Software FluoView FV31S and cellSens Dimension V3 (see Included Items for modules)

Configuration shown is for demonstration purposes. Contact us to discuss your application and needs for a customized quote.

Additional Details

  • Manufacturer: Olympus
  • Model:
  • Catalog Number: 51818
  • Serial Number:
  • Condition: Used
View full details